LIGO Document E080177-v2
- This specification is for the NVR cleanliness qualification by RGA testing of components (parts, assemblies) which are to be installed into the LIGO UHV system. This specification does not address particulate contamination requirements or qualification.
N.B.: This is a generalization of the specification (-v1) which was specifically for BSC suspension structures.
- Generalized the scope to apply to all components intended for service in the LIGO UHV system.
Improved the list of relevant documents (and generally removed references to specific versions and sections so as not to become outdated as these referenced documents evolve).
DCC Version 3.4.3, contact