LIGO Document E2100134-v6
- Following the initial FTIR results taken in HAM7 E2100122, 10x Hexane FTIR samples, (Labelled S1, S2...., S10), were taken in various grid locations. 2 of these samples were taken after attempting to clean with 2-propyl and DI water.
One of the attached documents lists the 10 areas we swabbed. eg Swab area 1 = vial labelled S1, and so on
4 additional Hexane test samples (using FTIR sample swabs). (Labelled T1, T2, T3, T4), were taken to use to attempt to determine the source of the contamination.
1 control was kept with each kit
The vials were shipped out in the same "kits" that they arrived (eg the vials that arrived in kit #1 and that we used were shipped out in kit #1 and so on).
SYS COMMENT: HAM7 CHAMBER FAILED FTIR.
VAC APPROVAL OR NOT: PENDING.
- v6: Version with results from JPL