LIGO Document D0900419-v2
- TMS first article installation (location H2-WBSC6).
NOTE - I checked and combined pdf works on Lenovo.
All BSC 3/8-16 dog clamp SHCS should be torqued to 300 inch lbs.
-
- Other Files:
- Sheet 6 and 7 only (D0900419 AdvLIGO SUS BSC6-H2, SHEETS 5 AND 6 ONLY FOR ...pdf, file is not accessible)
- eAssembly (D0900419 AdvLIGO SUS BSC6-H2, XYZ Local CS for ETM Te...EASM, file is not accessible)
- 1) V2 - Please note that v2 is sheets 1 through 5 from v1 plus sheets 6 and 7. Sheets 6 and 7 are new and include detailed hole call-outs for dog clamps and cookie cutter templates.
2) V2 - Please note that in the creation of sheets 6 and 7 that a discrepancy was found in cookie cutter hole call-out in D1101260. This was checked and red-lined in a new release of D1101260. IF YOU CAN TO CHOOSE D1101050-6 BSC6- B.
3) All BSC 3/8-16 dog clamp SHCS should be torqued to 300 inch lbs.
CIT
- LIGO-D0901880: aLIGO AOS SUS Transmission Monitor System (TMS, TMTS) Assembly
- LIGO-D1101064: Tooling for the ETM Transmission Monitor System (TMS)
- LIGO-D1002424: aLIGO, SUS, VIBRATION ABSORBER ASSY, 5LB VERTICAL WITH O-RINGS
- LIGO-D070056: Advanced LIGO, SUS, Quad N-PType, Quad Dog Clamp
- LIGO-D0902462: Cable Clamp Assembly, UHV Compatible
- LIGO-D1000234: CUSTOM CABLE V25X-TBD (Assembly)
- LIGO-D1000568: CUSTOM CABLE V25J-143
- LIGO-D1000921: CUSTOM CABLE V25C-143
- LIGO-D1003190: aLIGO SUS BSC Shorter Dog Clamp
- LIGO-D1100785: SUS Nitronic Flat Washers
- LIGO-D1100791: TMS SUS Cable Clamp Plate, Inner
- LIGO-D1100792: TMS SUS Cable Clamp Plate, Outer
DCC Version 3.4.3, contact