LIGO Document T2100286-v5

aLIGO Timing System Checks During O3B

Document #:
LIGO-T2100286-v5
Document type:
T - Technical notes
Other Versions:
Abstract:
Advanced LIGO (aLIGO) data is recorded by a data acquisition system (DAQ) that is driven entirely by the GPS-backed aLIGO Timing Distribution System. Several independent clocks’ 1PPS signals are used in timing diagnostics studies as witness signals. At each site, a Microsemi 4310b Cs-III Cesium-standard atomic clock checks for transient or short-term timing problems (see LIGO-T1700298 for details), and two CNS Clock II GPS clocks and a GPS-backed NTP server check for long-term/absolute timing problems.
We measured the time delay between aLIGO Timing Distribution System 1PPS and the aforementioned Timing Diagnostic System’s CNS Clock II GPS clock’s and and a GPS-backed NTP server’s 1PPS signals for the second half aLIGO’s third observation run (O3B). We also checked the atomic clock’s calibration during O3B. We also performed checks of the DuoTone time delays and IRIG-B timing outputs for the GW event candidates of O3B which can be found in LIGO-T2100348.
Files in Document:
Other Files:

DCC Version 3.4.3, contact Document Database Administrators