LIGO Document T1600066-v1
- The real-time code generator (RCG) uses IIR low-pass filters for data decimation to go from the sample rate of the input-output processor (iop) to the sample rate used by an individual RCG model. These filters are described in LIGO-T1500075. The purpose of this note is to define a new decimation filter for the RCG model rate of 16384 /sec.
- Erratum: The note describes the filter as being 6th order. This is wrong, the filter is 4th order (2 second-order-sections).
DCC Version 3.4.3, contact
Document Database Administrators