LIGO Document E1200625-v3
- The building local coordinates (gravity vector frame) of the centers of the ends of each support tube (for BSC and HAM chambers) are calculated. These values can be used to position (or check) that the support tubes are in the proper locations to place the ISI optics table in the proper location.
- corrected the positions of HAM1 and HAM6, accounting for the septum plate thickness.