ref. D1002732 v2, Changed to v3 The following 2 dimensions were changed: 1) .60" dimension was change from .71" 2) .375" dimension was changed from .43" 3) Zone B-4/5 4) REASON FOR CHANGE: The clamp was trimmed to allow it to contact a thinner Primary Mirror in the TMS telescope. 5) SIGNATURES REQUESTED: Ken Mailand Dennis Coyne 6) DCN DISTRIBUTION: Ken Mailand Calum Torrie Dennis Coyne