file://localhost
LIGO Production Large Actuator Test Report |
Actuator Serial #: L092
Operator Name: Gordon, Matt
Date: 11/19/2009 Time: 9:41 AM
Actuator Coil Resistance: 6.28 Ohms, PASS
Ambient Temperature: 67.9 F
Hi Pot Test Results: 1000 MOhms, PASS
X Travel Limit (inches): 0.539
Y Travel Limit (inches): 0.206
Z Travel Limit (inches): 0.507
|
X Position (in) |
Y Position (in) |
Z Position (in) |
Current (A) |
Force (lbs) |
Force Constant (lbs/A) |
PASS/FAIL |
Center |
0.000 |
0.000 |
0.000 |
2.094 |
20.091 |
9.595 |
PASS |
Position 1 |
0.250 |
0.080 |
0.217 |
2.387 |
20.164 |
8.445 |
PASS |
Position 2 |
0.250 |
-0.080 |
0.217 |
2.535 |
20.259 |
7.993 |
PASS |
Position 3 |
-0.250 |
-0.080 |
0.217 |
2.455 |
20.207 |
8.232 |
PASS |
Position 4 |
-0.250 |
0.080 |
0.217 |
2.389 |
20.124 |
8.424 |
PASS |
Position 5 |
-0.250 |
0.080 |
-0.217 |
2.355 |
20.312 |
8.626 |
PASS |
Position 6 |
-0.250 |
-0.080 |
-0.217 |
2.317 |
19.977 |
8.622 |
PASS |
Position 7 |
0.250 |
-0.080 |
-0.217 |
2.237 |
19.956 |
8.919 |
PASS |
Position 8 |
0.250 |
0.080 |
-0.217 |
2.282 |
19.943 |
8.741 |
PASS |
Center |
0.000 |
0.000 |
0.000 |
-2.144 |
-20.234 |
9.436 |
PASS |
Position 1 |
0.250 |
0.080 |
0.217 |
-2.350 |
-19.957 |
8.491 |
PASS |
Position 2 |
0.250 |
-0.080 |
0.217 |
-2.386 |
-20.322 |
8.517 |
PASS |
Position 3 |
-0.250 |
-0.080 |
0.217 |
-2.348 |
-19.984 |
8.512 |
PASS |
Position 4 |
-0.250 |
0.080 |
0.217 |
-2.341 |
-19.976 |
8.533 |
PASS |
Position 5 |
-0.250 |
0.080 |
-0.217 |
-2.454 |
-20.133 |
8.205 |
PASS |
Position 6 |
-0.250 |
-0.080 |
-0.217 |
-2.411 |
-19.944 |
8.271 |
PASS |
Position 7 |
0.250 |
-0.080 |
-0.217 |
-2.281 |
-19.961 |
8.750 |
PASS |
Position 8 |
0.250 |
0.080 |
-0.217 |
-2.396 |
-20.261 |
8.457 |
PASS |
QNA-TSG
1901 South Harbor City Blvd
Suite 700
Melbourne, FL 32901
Contact: Scott Stewart
scott.stewart@plansys.com
321-768-6500 x11