LIGO Production Large Actuator Test Report |
Actuator Serial #: L006
Operator Name: Smith, Lane
Date: 8/12/2009 Time: 7:20 AM
Actuator Coil Resistance: 6.39 Ohms, PASS
Ambient Temperature: 68.0 F
Hi Pot Test Results: 1000 MOhms, PASS
X Travel Limit (inches): 0.517
Y Travel Limit (inches): 0.214
Z Travel Limit (inches): 0.484
|
X Position (in) |
Y Position (in) |
Z Position (in) |
Current (A) |
Force (lbs) |
Force Constant (lbs/A) |
PASS/FAIL |
Center |
0.000 |
0.000 |
0.000 |
2.057 |
20.287 |
9.862 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
2.534 |
20.136 |
7.948 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
2.435 |
20.051 |
8.233 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
2.371 |
19.837 |
8.365 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
2.334 |
19.923 |
8.534 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
2.315 |
20.025 |
8.650 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
2.355 |
20.072 |
8.522 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
2.320 |
20.072 |
8.652 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
2.318 |
20.064 |
8.657 |
PASS |
Center |
0.000 |
0.000 |
0.000 |
-2.091 |
-20.026 |
9.576 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
-2.327 |
-20.166 |
8.668 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
-2.271 |
-20.079 |
8.841 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
-2.253 |
-20.166 |
8.949 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
-2.355 |
-20.224 |
8.586 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
-2.464 |
-20.028 |
8.127 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
-2.424 |
-19.968 |
8.239 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
-2.373 |
-19.844 |
8.362 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
-2.376 |
-20.218 |
8.508 |
PASS |