file://localhost
LIGO Production Large Actuator Test Report |
Actuator Serial #: L025
Operator Name: Smith, Lane
Date: 8/12/2009 Time: 10:56 AM
Actuator Coil Resistance: 6.39 Ohms, PASS
Ambient Temperature: 71.3 F
Hi Pot Test Results: 1000 MOhms, PASS
X Travel Limit (inches): 0.523
Y Travel Limit (inches): 0.205
Z Travel Limit (inches): 0.503
|
X Position (in) |
Y Position (in) |
Z Position (in) |
Current (A) |
Force (lbs) |
Force Constant (lbs/A) |
PASS/FAIL |
Center |
0.000 |
0.000 |
0.000 |
2.208 |
20.339 |
9.210 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
2.371 |
19.828 |
8.363 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
2.252 |
20.076 |
8.914 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
2.275 |
19.910 |
8.750 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
2.415 |
20.015 |
8.286 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
2.312 |
20.045 |
8.671 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
2.407 |
20.291 |
8.429 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
2.383 |
19.922 |
8.359 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
2.316 |
20.105 |
8.681 |
PASS |
Center |
0.000 |
0.000 |
0.000 |
-2.093 |
-19.925 |
9.521 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
-2.323 |
-20.221 |
8.705 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
-2.288 |
-20.047 |
8.763 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
-2.291 |
-19.907 |
8.689 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
-2.338 |
-20.152 |
8.618 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
-2.505 |
-19.924 |
7.954 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
-2.494 |
-19.832 |
7.952 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
-2.398 |
-20.187 |
8.420 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
-2.482 |
-20.078 |
8.091 |
PASS |
QNA-TSG
1901 South Harbor City Blvd
Suite 700
Melbourne, FL 32901
Contact: Scott Stewart
scott.stewart@plansys.com
321-768-6500 x11
© 2009 QinetiQ North America, Technology Solutions Group |