file://localhost
LIGO Production Large Actuator Test Report |
Actuator Serial #: L017
Operator Name: Smith, Lane
Date: 8/11/2009 Time: 3:54 PM
Actuator Coil Resistance: 6.33 Ohms, PASS
Ambient Temperature: 74.2 F
Hi Pot Test Results: 1000 MOhms, PASS
X Travel Limit (inches): 0.516
Y Travel Limit (inches): 0.196
Z Travel Limit (inches): 0.480
|
X Position (in) |
Y Position (in) |
Z Position (in) |
Current (A) |
Force (lbs) |
Force Constant (lbs/A) |
PASS/FAIL |
Center |
0.000 |
0.000 |
0.000 |
2.127 |
20.234 |
9.513 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
2.522 |
20.235 |
8.024 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
2.316 |
20.422 |
8.818 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
2.381 |
20.126 |
8.453 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
2.469 |
20.103 |
8.144 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
2.400 |
20.088 |
8.368 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
2.355 |
19.915 |
8.458 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
2.301 |
19.999 |
8.690 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
2.446 |
20.051 |
8.198 |
PASS |
Center |
0.000 |
0.000 |
0.000 |
-2.091 |
-19.929 |
9.531 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
-2.309 |
-20.225 |
8.760 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
-2.262 |
-20.051 |
8.866 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
-2.286 |
-20.111 |
8.798 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
-2.341 |
-20.245 |
8.648 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
-2.317 |
-20.254 |
8.742 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
-2.257 |
-20.099 |
8.904 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
-2.250 |
-20.052 |
8.910 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
-2.312 |
-20.217 |
8.743 |
PASS |
QNA-TSG
1901 South Harbor City Blvd
Suite 700
Melbourne, FL 32901
Contact: Scott Stewart
scott.stewart@plansys.com
321-768-6500 x11
© 2009 QinetiQ North America, Technology Solutions Group |