file://localhost
LIGO Production Large Actuator Test Report |
Actuator Serial #: L027
Operator Name: Smith, Lane
Date: 8/12/2009 Time: 1:24 PM
Actuator Coil Resistance: 6.41 Ohms, PASS
Ambient Temperature: 69.5 F
Hi Pot Test Results: 1000 MOhms, PASS
X Travel Limit (inches): 0.525
Y Travel Limit (inches): 0.205
Z Travel Limit (inches): 0.505
|
X Position (in) |
Y Position (in) |
Z Position (in) |
Current (A) |
Force (lbs) |
Force Constant (lbs/A) |
PASS/FAIL |
Center |
0.000 |
0.000 |
0.000 |
2.147 |
20.189 |
9.404 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
2.420 |
19.995 |
8.261 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
2.333 |
20.145 |
8.635 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
2.442 |
20.032 |
8.203 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
2.370 |
20.062 |
8.466 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
2.320 |
20.171 |
8.696 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
2.296 |
20.028 |
8.724 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
2.333 |
20.044 |
8.593 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
2.317 |
20.218 |
8.728 |
PASS |
Center |
0.000 |
0.000 |
0.000 |
-2.115 |
-19.905 |
9.410 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
-2.392 |
-20.187 |
8.440 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
-2.340 |
-20.056 |
8.573 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
-2.282 |
-19.838 |
8.693 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
-2.350 |
-19.935 |
8.481 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
-2.414 |
-20.002 |
8.284 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
-2.453 |
-19.997 |
8.151 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
-2.396 |
-19.916 |
8.312 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
-2.400 |
-20.068 |
8.363 |
PASS |
QNA-TSG
1901 South Harbor City Blvd
Suite 700
Melbourne, FL 32901
Contact: Scott Stewart
scott.stewart@plansys.com
321-768-6500 x11
© 2009 QinetiQ North America, Technology Solutions Group |