file://localhost
LIGO Production Large Actuator Test Report |
Actuator Serial #: L015
Operator Name: Smith, Lane
Date: 8/12/2009 Time: 5:17 PM
Actuator Coil Resistance: 6.34 Ohms, PASS
Ambient Temperature: 72.4 F
Hi Pot Test Results: 1000 MOhms, PASS
X Travel Limit (inches): 0.531
Y Travel Limit (inches): 0.196
Z Travel Limit (inches): 0.481
|
X Position (in) |
Y Position (in) |
Z Position (in) |
Current (A) |
Force (lbs) |
Force Constant (lbs/A) |
PASS/FAIL |
Center |
0.000 |
0.000 |
0.000 |
2.196 |
19.903 |
9.063 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
2.466 |
20.079 |
8.141 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
2.383 |
19.877 |
8.343 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
2.327 |
20.038 |
8.612 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
2.418 |
19.993 |
8.267 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
2.356 |
20.281 |
8.608 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
2.395 |
20.154 |
8.417 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
2.374 |
20.174 |
8.498 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
2.351 |
20.291 |
8.632 |
PASS |
Center |
0.000 |
0.000 |
0.000 |
-2.123 |
-20.033 |
9.437 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
-2.346 |
-20.100 |
8.569 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
-2.323 |
-20.001 |
8.611 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
-2.318 |
-20.084 |
8.666 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
-2.379 |
-20.144 |
8.467 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
-2.564 |
-20.058 |
7.823 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
-2.582 |
-19.857 |
7.691 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
-2.458 |
-20.049 |
8.157 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
-2.415 |
-19.969 |
8.268 |
PASS |
QNA-TSG
1901 South Harbor City Blvd
Suite 700
Melbourne, FL 32901
Contact: Scott Stewart
scott.stewart@plansys.com
321-768-6500 x11
© 2009 QinetiQ North America, Technology Solutions Group |