file://localhost
LIGO Production Large Actuator Test Report |
Actuator Serial #: L012
Operator Name: Smith, Lane
Date: 8/12/2009 Time: 11:18 AM
Actuator Coil Resistance: 6.39 Ohms, PASS
Ambient Temperature: 70.6 F
Hi Pot Test Results: 1000 MOhms, PASS
X Travel Limit (inches): 0.523
Y Travel Limit (inches): 0.204
Z Travel Limit (inches): 0.506
|
X Position (in) |
Y Position (in) |
Z Position (in) |
Current (A) |
Force (lbs) |
Force Constant (lbs/A) |
PASS/FAIL |
Center |
0.000 |
0.000 |
0.000 |
2.129 |
20.085 |
9.432 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
2.483 |
20.046 |
8.073 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
2.388 |
20.028 |
8.385 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
2.416 |
20.076 |
8.311 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
2.405 |
19.857 |
8.255 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
2.300 |
20.015 |
8.704 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
2.400 |
20.210 |
8.420 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
2.399 |
19.837 |
8.269 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
2.328 |
20.081 |
8.626 |
PASS |
Center |
0.000 |
0.000 |
0.000 |
-2.149 |
-20.159 |
9.381 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
-2.373 |
-20.111 |
8.476 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
-2.337 |
-19.905 |
8.517 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
-2.336 |
-20.075 |
8.592 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
-2.388 |
-20.210 |
8.462 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
-2.433 |
-19.963 |
8.206 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
-2.458 |
-20.069 |
8.164 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
-2.407 |
-19.898 |
8.267 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
-2.378 |
-20.010 |
8.413 |
PASS |
QNA-TSG
1901 South Harbor City Blvd
Suite 700
Melbourne, FL 32901
Contact: Scott Stewart
scott.stewart@plansys.com
321-768-6500 x11